The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Magnetic resonance electrical properties tomography (MR‐EPT) is a technique used to estimate the conductivity and permittivity of tissues from MR measurements of the transmit magnetic field. Different reconstruction methods are available; however, all these methods present several limitations, which hamper the clinical applicability. Standard Helmholtz‐based MR‐EPT methods are severely affected by...
Purpose
MR electrical properties tomography (MR‐EPT) aims to measure tissue electrical properties by computing spatial derivatives of measured
data. This computation is very sensitive to spatial fluctuations caused, for example, by noise and Gibbs ringing. In this work, the error arising from the computation of spatial derivatives using finite difference kernels (FD error) has been investigated...